Common Faults · Pump & Valve Faults (Quick-Reference Handbook)
Centrifugal pump cavitation fault
[Phenomenon] Pump emits crackling / metal-impact sounds, head drops, flow fluctuates, vibration
[Cause] (1) NPSHa < NPSHr (installation too high or high inlet resistance); (2) Inlet blockage; (3) Liquid temperature too high; (4) Inlet vortexing
[Diagnosis] Listen for crackling, measure sudden head drop, check inlet pressure gauge fluctuation
[Remedy] Lower installation height, enlarge inlet pipe diameter, clean inlet strainer, reduce liquid temperature, increase inlet submergence depth ≥ 0.5 m
Other related quick references:Welding defectsHydraulic systemPneumatic systemMotor electricalEquipment faultsMotor faultsStructural part faultsSensor faultsElectrical faultsQuick diagnosisMechanical component faultsBearing faultsGear faultsHydraulic / pneumatic valves