Common Faults · Standard Equipment Faults (Quick-Reference Handbook)
Pressure vessel leakage analysis
[Phenomenon] Medium leakage occurs under operating pressure
[Cause] (1) Corrosion thinning (uniform / pitting / stress-corrosion); (2) Fatigue crack; (3) Weld defect (incomplete penetration / porosity / slag inclusion); (4) Seal face damage
[Diagnosis] Penetrant testing PT to find surface cracks; magnetic particle MT for carbon-steel surfaces; ultrasonic thickness gauging to locate thinned zones; acoustic emission for online monitoring
[Remedy] Build up by welding or plate bonding for thinning; grind and weld for cracks; excavate and reweld weld seams then heat treatment + NDT; re-turn seal face + replace gasket
Air compressor discharge temperature too high
[Phenomenon] Discharge temperature > 110°C (alarm) and auto-shutdown above 120°C
[Cause] (1) Poor cooler heat dissipation (fin fouling or scale); (2) Insufficient or degraded lubricant; (3) High ambient temperature; (4) Oil cooler failure
[Diagnosis] Check cooler inlet/outlet water temp difference (normal 5~15°C); check oil level; measure ambient temperature
[Remedy] Clean cooler fins or tube bundle; replace lubricant; improve equipment-room ventilation
Other related quick references:Welding defectsHydraulic systemPneumatic systemMotor electricalEquipment faultsMotor faultsStructural part faultsSensor faultsElectrical faultsQuick diagnosisMechanical component faultsBearing faultsGear faultsHydraulic / pneumatic valves