Jog control means the motor runs only while the button is held and stops the moment it is released, used for machine tool setting and crane jogging. This page lists what every part does and how current flows from the button to the contactor coil.
A jog circuit needs four core parts: a three-phase breaker as main switch, a fuse or breaker for short-circuit protection, an AC contactor KM whose main contacts switch the motor and whose coil is the control heart, and a normally open jog button SB that closes only while pressed. The power path is L1 L2 L3 to breaker to KM main to motor; the control path is L to SB to KM coil to N, energizing the coil.
Pressing SB completes the control loop and the KM coil draws about 0.1 to 0.5 ampere, making the magnet pull in the armature so the main contacts close and the motor spins. Release SB and the coil de-energizes, the spring opens the contacts and the motor stops. There is no latch, so it stops the instant you let go, which is the key difference from latching control. Match coil voltage to the supply taken: L1-L2 gives 380 V, L-N gives 220 V.
| Part | Role | Sizing |
|---|---|---|
| Breaker | main switch | 1.5-2.5x motor |
| Fuse | short protect | with contactor |
| Contactor KM | switch main | coil match |
| Jog button SB | NO jog | press to close |
| OL relay | overload | rated current |
| Motor | actuator | power match |
Use jog control where frequent start-stop and manual intervention are needed: tool setting, crane jogging, hoist fine adjust, single-stroke presses. Route the control loop on separate wire, mount the button within reach, and keep main and button wires in separate conduits. Test jog before any latching function, safety first.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Low-voltage devices follow GB/T 14048 with IEC 60947; drawing symbols follow JIS C 0617 equal to IEC 60617. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.