Application of delayed control in equipment cooling and lubrication

Cutting cooling and lubrication the instant a machine stops is the cause of burned bearings and scored bushes. This note covers the wiring and setting of delay in cooling fans, lube pumps and central oil stations so the machine is cared for after stop, no dry wear.

1. How it works

Spindle motor, inverter, servo still hold much residual heat after stop, must delay cooling. Wiring: off-delay relay or PLC timer controls the cooling fan contactor, after main motor stops fan runs on 10 to 30 seconds. Time by thermal capacity, larger machine larger. Also temperature sensor closed loop: fan stops only when temperature falls below threshold, easier. Either way the fan off-delay hard wire or program must be reliable, not by someone remembering to switch off.

2. Numbers and practice

Large machine after stop, guides, screws, bearings still need last-pass lube or next start is dry wear. Wiring: after stop lube pump or central station delays 3 to 10 seconds to send oil to friction faces; pair with pressure switch to confirm delivery. For timed auto-lube, after stop run one more lube cycle then stop. Set by lube circuit volume and pipe length so the far end is lubed.

3. Pitfalls and fixes

Set cooling and lube delay to match the machine: too short residual heat not gone, oil not there, still burns; too long wastes power and machine will not stop affecting next step. Interlock the delay with main motor stop, delay starts the instant main stops; even on fault e-stop let cooling lube finish then stop to prevent heat build. Accept simulate stop, stopwatch the actual fan and pump continuation, confirm matches set, and measure temperature to verify cooling.

4. Cooling lube sheet

ItemObjectTimeBasis
Cool fanOff-delay10-30sThermal
Lube pumpOff-delay3-10sVolume
ClosedTemp thrTo thrSensor
InterlockStop syncSyncNo miss
E-stopFinishNo heatSafety
AcceptStopwatchTempMatch

5. Notes

Cooling fan off-delay 10 to 30 s heat, lube pump 3 to 10 s oil, set by thermal and volume. Delay interlocked with main stop, e-stop also finish cooling lube then stop. Accept stopwatch continuation and temperature verify, too short burns, too long wastes.

6. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Equipment cooling lube and protection per GB/T 5226.1 and GB 755, IEC 60204-1. Always check the device datasheet and the product design file for ratings and derating.

7. Cautions

⚠️ Three common pitfalls:
① Too short: heat burn
② Lube not there: dry
③ By memory: forget burn

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.