After wiring, the table will not reciprocate, usually a swapped contact, missing interlock or wrong limit. This note groups faults by symptom, no start, no swap, overrun, noise, with a lookup table and order so a beginner locates the break in ten minutes with a meter.
Neither direction moves after closing: first check the main supply and main stop chain conduct and the overload has not tripped. Forward only, no reverse, means a break in the reverse branch: check reverse start, reverse self-hold, SQ1 NC, forward auxiliary NC interlock series. Common is SQ1 NC pressed or reversed to NO, or the forward interlock NC omitted so reverse cannot self-hold. Buzzer along the reverse branch segment by segment, the silent one is the break.
Running past the end and overrun is limit failure: check the end switch is reached, its NC opens, roller not jammed or welded; if reached but not open the switch is bad or welded; if never reached the cam moved or switch tilted. Swaps only once then stops means the other end NO not paralleled to start or poor contact. Buzzing or chattering contactor means unreliable interlock letting both directions pull, or low voltage; stop immediately or burn main contacts. Order: dead then live, chain then point, supply then control; retest reciprocation after each fix.
| Symptom | Cause | Method |
|---|---|---|
| No move | Main break/OL | Chain OL |
| One way | Reverse break | Buzz rev |
| Overrun | Limit/cam | Reach switch |
| Swap once | NO not par | Check SQ |
| Buzz | Interlock | Aux NC |
| Chatter | Cam rebound | Mechanic |
Faults by symptom: no start checks main chain overload, one way checks reverse branch interlock, overrun checks limit cam, noise checks interlock contacts. Order dead then live, chain then point, supply then control; retest after each fix, do not deliver after one.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Fault finding per GB/T 5226.1 chapter 6, switch per GB/T 14048.5. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.