A moving machine must not crash into its end stop; that is the job of limit control and travel switches. This note explains how the switch cuts power at the end, what it series with, terminal and extreme double protection, and the mechanical and electrical wiring of the switch.
The core is one or more travel switches at the end of travel; when the mechanism hits the cam, the switch actuates and cuts the directional contactor coil, stopping the motor. The NC contact series in that direction branch conducts at rest and opens on impact, releasing the contactor. Pure hardware protection independent of human reaction, the last gate against crash. The limit usually only cuts the directional contactor, not reverse or main supply, so the machine can be backed off.
Use the NC contact series in the forward or reverse control branch. For forward: forward start, forward self-hold and forward limit NC series feed the forward coil; at travel end the switch opens, forward releases, motor stops. Reverse is similar, with hard interlock between directions. Mount the roller facing the cam, position adjustable, coarse then fine. Important machines add an extreme limit further out, its NC series in the main stop chain, cutting main power if the working limit fails. Acceptance triggers both switches separately, confirming direction stop and main cut.
| Protection | Position | Contact | Action |
|---|---|---|---|
| Working | Travel end | NC in dir | Stop dir |
| Extreme | Further out | NC main | Cut main |
| Switch | Roller to cam | Adjust | Coarse fine |
| Interlock | F/R contactor | Hard | No both |
| Reset | Manual auto | Off cam | Confirm |
| Accept | Trigger both | Double | Sign |
Limit control is the hardware last gate against crash, NC in direction branch stops at end. Add an extreme limit in main chain for double protection, spaced by braking distance. Mount roller to cam, adjustable, accept by triggering both.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Mechanical electrical safety per GB/T 5226.1 and GB 5083, switch per GB/T 14048.5. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.