Set a thermal relay too high and the motor burns before it trips; too low and it trips production dry. One dial stands between protection and output. This page walks the calculation, nameplate versus branch currents for star-delta and two-speed machines, temperature corrections, and the adjustment and verification routine.
Step one sets the base current: take the nameplate rating for ordinary cage motors; for star-delta starters split the location, winding current runs about 0.58 of line current at speed, so a relay in the winding branch sets to winding current while one in the line sets to line current; two-speed machines take one relay per speed at its own nameplate; VFD-fed motors need electronic protection since ordinary thermal elements respond poorly to high-frequency content. Step two sets the dial to the base, within a plus-or-minus five to ten percent trim. Step three corrects for environment: sustained cabinet temperatures above forty degrees follow the maker compensation curve, compensated relays skip it, and altitudes above 2000m take a three to five percent reduction for poorer cooling.
Know the dial structure before turning anything: most relays cover a band like 12~20A within one rating, so choose a model whose mid-band holds the setting rather than the edge. Adjust with the motor stopped, align the dial to the base current, then verify the characteristic: 1.05 times the setting must hold for two hours, 1.2 times must trip within twenty minutes, 1.5 times within two minutes per GB/T 14048.4; on site without a test rig, at least clamp the running current, and a persistent value above ninety-five percent of the setting means the dial is tight. Two prohibitions: never bypass the relay straight to the motor, and never treat the dial as a running-current trim, repeated twisting wears the mechanism and the setting drifts.
Two failure directions get two playbooks. Nuisance trips (no overload, still trips): tight setting, starting time beyond the trip class, hot terminals from poor crimps, or stacked ambient heat, ventilate or fit compensated types. Failure to trip (overloaded, no trip): loose setting, phase current imbalance slowing the response, check the three-phase balance, and single-phasing, which demands a phase-failure-protective relay since ordinary three-phase elements react slowly. Annual verification on a test rig against the factory curve, replace beyond ten percent deviation, and keep settings archived against running-current logs so load degradation shows as a trend before it becomes a burnout.
| Stage | Key point | Typical value | Verification |
|---|---|---|---|
| Base current | Nameplate or branch current | Line rating for ordinary duty | Against nameplate |
| Star-delta branch | Winding current about 0.58 of line | Per relay location | Two relays, split |
| Two-speed motors | One setting per speed | Such as 12A and 15A | Each to its own |
| Ambient correction | Above 40C per curve | Compensated types skip | Maker curve |
| Trip characteristic | 1.2 times trips in 20min | Standard characteristic | Test-rig annual check |
| Phase-failure protection | Phase-failure type required | 1.05 times within 2h | Missing-phase test |
Run the setting job down this table and archive the results. The principle is to follow the nameplate, not folklore: the nameplate is the base, corrections have documented grounds, and every adjustment gets verified. Settings versus running currents, compared over time, keep protection and output in balance for years.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Thermal relay trip characteristics and phase-failure requirements follow GB/T 14048.4 (IEC 60947-4-1); motor ratings and duty types refer to GB/T 755. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.