A two-speed circuit needs three contactors with clear duties; a wrong configuration burns windings or trips endlessly. This page assigns KM1, KM2 and KM3 their roles, sizes each one, and states the interlock level the standards expect.
The standard delta/double-star main circuit assigns KM1 as the low-speed supply contactor on U1V1W1, sized to the low-speed winding current; KM2 as the high-speed supply contactor on U2V2W2, sized to the high-speed current; and KM3 as the shorting contactor, closing U2V2W2 together for low-speed delta or U1V1W1 into a neutral point for high speed. KM3 carries nearly zero current in balanced steady state but must still be rated at half the high-speed current or better, with contacts matching the main circuit for spare-part commonality. KM2 and KM3 must pick up together, enforced by wiring, or a lone pickup leaves the winding open or phase-less.
Size by nameplate: the high-speed current typically runs 1.1 to 1.4 times the low-speed value for constant-power windings. Choose AC-3 duty ratings at least equal to the corresponding winding current plus ten to twenty percent margin. A 5.5/7.5kW four-pole and two-pole motor draws about 12A at low speed and 15A at high, so KM1 takes a 12A AC-3 frame and KM2 a 16A one, KM3 matching KM2. Frequent jogging or plugging moves the duty to AC-4 or one frame up per the derating curves. Coil voltage matches the control supply, and auxiliary contacts must cover interlocks and lamps, extending through interposing relays when short.
Interlock depth scales with criticality: minimum is electrical interlock both directions; standard adds mechanical linking so the two states cannot physically coexist; critical machines add selector switches and changeover permission conditions. GB/T 5226.1 requires interlocking where simultaneous functions create a hazard, and two winding connections energized together burn the motor outright. Test annually: jumper a KM1 latch contact and press the high-speed button, KM2 and KM3 must refuse with an alarm; drop the control supply during run, all contactors must release and nothing may self-start on restoration, proving zero-voltage protection.
| Contactor | Duty | Current rating | Key requirement |
|---|---|---|---|
| KM1 low-speed supply | Feeds U1V1W1 | At least 1.1 times low-speed current | AC-3 utilization category |
| KM2 high-speed supply | Feeds U2V2W2 | At least 1.1 times high-speed current | Picks up together with KM3 |
| KM3 shorting contactor | Makes delta or neutral short | At least 0.5 times high-speed current | Contacts match main circuit |
| Auxiliary contacts | Interlocks and lamps | Counted from the drawing | Extend via interposing relay |
| Coil voltage | Matches control supply | 85%~110% tolerance | Never mix AC and DC |
| Thermal relays | Split protection | One set per speed | Set to each winding current |
Verify configuration and acceptance against this table. The core is clear duty plus guaranteed exclusivity: who feeds, who shorts, who is locked out, every line unambiguous, every rating one notch above the nameplate current, spares matched by specification.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Contactor utilization categories and ratings follow GB/T 14048.4; interlock requirements refer to GB/T 5226.1 clause 9. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.