A few millimetres off in mounting the switch and the table stops early or overruns, ruining accuracy. This note quantifies error sources, axial skew, spacing, overtravel, rebound, gives compensation and acceptance so error stays within a millimetre.
Error one axial skew: roller axis not perpendicular to motion, contact point off when pressed, effective overtravel shrinks, causing early stop or miss, deviation 2 to 5 mm. Error two spacing: free gap between cam and switch wrong, large gap overruns, small gap stops early or jams the switch. Error three overtravel wrong: rated 2 to 5 mm not set, too small misfires, too large stops early. Error four rebound: spring cam rebounds after arrival releasing the switch, start-stop chatters.
These stack and degrade repeat accuracy from designed plus minus 0.5 mm to over plus minus 3 mm, even overrun crash. Axial skew and spacing are systematic, always off the same way; overtravel and rebound are random, come and go hardest to find. Tell systematic from random: systematic adjust mechanically, random check switch and cam rebound, act accordingly. Compensation: adjustable switch bracket to set perpendicularity and position, feeler gauge for 1 to 2 mm gap; adjustable screw cam to kill spacing error; switch with adjustable roller arm to unify overtravel. Accept by trial: ten auto runs measure each end stop, deviation under 1 mm; dial gauge the switch action point against cam position. Monthly recheck, tighter on vibrating machines.
| Source | Deviation | Effect | Fix |
|---|---|---|---|
| Axial skew | 2-5mm | Miss/early | Perp |
| Spacing | Big over small | Off pos | Gap |
| Overtravel | Misfire/early | Random | Set press |
| Rebound | Chatter | Random | Less reb |
| Sys bias | Same way | Mech | Bracket |
| Accept | Ten<1mm | Dial | Monthly |
Four mount errors: axial skew, spacing, overtravel, rebound, stack to degrade accuracy from plus minus 0.5 to over 3 mm even overrun. Systematic adjust mechanically, random check switch rebound; compensation adjustable bracket and screw, unify overtravel; accept ten runs under 1 mm, dial gauge consistency.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Position accuracy and mounting per GB/T 5226.1 and GB/T 17421. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.