Reciprocating failure is not always wrong wiring; often it is poor travel-switch contact, intermittent make-break that stalls the table at one end. This note covers three-step diagnosis with meter, scope and swap, and handling oxidation, spring fatigue and dust, for the intermittent fault that escapes hours of checking.
The symptom of poor contact is intermittent: sometimes normal, sometimes the table fails to move or stop at one end, and a tap on the switch fixes it. Unlike a fixed wiring fault it comes and goes. If the fault always appears at the same end and a light tap restores it, ninety percent it is that switch contact. First record which end and which motion fails, narrowing to SQ1 or SQ2, do not tear the whole wire.
Three-step diagnosis: one, de-energised, meter the NC and NO contacts, check crisp transition between zero and infinite ohms on press and release; a few hundred ohms or flickering means poor contact. Two, energised, scope or volt-meter the contact ends for transient dropouts on actuation. Three, swap in a new switch and run; if the fault vanishes it is confirmed. From simple to complex, rarely wrong. Types: oxidation, clean with fine paper or contact restorer or replace; spring fatigue, low contact force, replace whole; dust and oil causing tracking or jam, better box and blow-out. After fix run fifty reciprocations with no failure; maintain by periodic cleaning and resistance check.
| Symptom | Diagnose | Fix | Accept |
|---|---|---|---|
| Intermittent | Dead meter | Clean swap | Fifty |
| Same end | Ohm jump | That switch | Locate |
| Tap fixes | Scope glitch | Swap | Confirm |
| Oxide | Dark surface | Paper | Ohm |
| Spring | Low force | Replace | Force |
| Dust | Jam track | Box blow | Strong |
Intermittent failure is mostly poor contact, seen at one end and fixed by a tap. Diagnose by dead-meter, live-scope, swap. Oxidation clean, spring fatigue replace, dust better box. After fix fifty runs no failure; maintain by periodic cleaning and resistance check.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Switch maintenance per GB/T 14048.5 and GB/T 5226.1, IEC 60947-5-1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.