MOULDLKnowledge BaseElectrical Knowledge Base3D Model DownloadsMembership
中文版Model Store »
Knowledge Base › Electrical Knowledge Base › Letter codes and graphic symbols: the pairing rules on electrical drawings
HomeModels
Table of contents

On this page

Electrical Control & Drawings (500 articles)

Quick Reference

Letter codes and graphic symbols: the pairing rules on electrical drawings

The graphic symbol says what is drawn and the letter code says what it is called, and the two must agree. This page explains the GB/T 7159 code system, how codes pair with symbols, and how reference numbers are assigned.

1. How it works

The national system uses one letter for the device class: K for relays and contactors, M for motors, Q for switchgear, F for protection, R for resistors, C for capacitors, G for supply sources, E for miscellaneous devices, B for converters and measuring transducers. Two-letter codes refine the class: KM contactor, KA relay, QF breaker, FU fuse, FR thermal relay. Every graphic symbol must carry its letter code plus a serial number such as KM1 or QF2, and a reader identifies the class from the letter first and the detail from the graphic.

2. Practice and pitfalls

The pairing rule is one graphic symbol per letter code, written beside the symbol or in the terminal list; identical devices are separated by serial numbers such as KM1 and KM2. When the graphic is simplified, for example only the coil drawn, all its scattered contacts carry the same code with suffixes to show they belong to one device. The text code must never contradict the graphic: a breaker symbol labelled FU is a purchasing error waiting to happen, so codes, material list and terminal strip must all agree.

3. Letter codes paired with graphic symbols table

Single letterClassDouble letter examplesSymbol link
Krelays and contactorsKM KA KTcoil plus contacts
MmotorsMcircle with M
QswitchgearQF QSbox or knife symbol
FprotectionFU FRwave or heating mark
BtransducersTA TVcircle with pierce line

4. Notes

Letter code and graphic symbol must pair one to one, with the code beside the symbol and consistent with the material list and terminal strip. Simplified graphics keep the same code with suffixes on every scattered contact, and the reference table ships with the drawing so the wireman never hunts for a device.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Letter code system per GB/T 7159, corresponding to IEC 61346; paired graphics per GB/T 4728. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Contactor symbol labelled with code FU: the buyer purchases fuses instead of a contactor
② Auxiliary contact missing its code suffix: nobody can tell which coil the contact belongs to
③ Serial numbers skipping and mixed case: drawing and hardware never reconcile

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.

Related reading

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Electrical Knowledge Base · free self-study reference for electrical & automation engineers, 3D CAD models at MOULDL