When lamps are dark or wrong, the operator is blind. This page explains how to design indicator circuits so states are clear and misjudgement is impossible.
Indicators must reflect key states: power on-off, running or stopped, fault alarms, station ready, safety gate state and motor overload. One lamp expresses one clear state. Colours follow the code: red for stop or fault, green for run, yellow for warning or standby, blue for forced or special, white for general. Alarm lamps flash or buzz to grade severity. Never share one colour between run and fault, confusion causes accidents.
Lamps are driven by auxiliary contacts of control relays or PLC outputs, at the control circuit voltage of 24 V, 110 V or 220 V. LED lamps take series current limiting, a few mA up to 20 mA by rating. Sum the current when lamps share one supply and keep margin. Drive fault lamps from hard-wired safety circuits rather than software so the report is real. For remote lamps check voltage drop and enlarge wire size, especially on 24 V circuits. Wet or dusty places need lamps of matching protection rating.
Field mistakes: colours used arbitrarily so red and green mislead the operator; one lamp carrying several states so nobody knows what happened; fault lamps driven by PLC software, dead when the PLC crashes; remote 24 V lamps never drop-checked, dim beyond reading. Do it right: one lamp one state, colour by code, hard-wired alarms, drop check on long runs, protection matched. Map indicator logic to the wiring diagram so the operator reads the machine at a glance and misoperation drops by half.
| Colour | Meaning | Usage |
|---|---|---|
| Red | Stop fault | Hard wired |
| Green | Running | Normal |
| Yellow | Warning standby | Hint |
| Blue | Forced special | Specific |
| White | General | Auxiliary |
Indicator design rests on clear states, coded colours, hard-wired alarms and drop checks at low voltage. One lamp one state, red green yellow blue white per code, logic mapped to the drawing; the operator understands at a glance and missed alarms plus misoperation drop sharply.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Indicator lamps see GB/T 4025 (IEC 60073), electrical safety see GB/T 5226.1, low-voltage apparatus see GB/T 14048. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.