The maintenance manual is not for the designer but for the fitter doing night breakdown repair. How codes (KM1) are organised in the manual decides whether he finds the fix in three minutes. Here is how to use codes in the manual.
Organise: build one entry per component code, KM1 one entry, M1 one entry, each with function, parameters, common faults and fix steps, fastest to search; pair with a fault tree from symptom (motor no run) down to code (check if KM1 pulls in, if QF1 tripped); attach drawing position (sheet plus coordinate) and physical position (cabinet location) for double locating; mark the spare part number on key codes so a failure reports purchase directly; use a QR code linking code to manual page, drawing and BOM, all out with one scan.
Writing notes: the code must match the live drawing and hardware exactly, one wrong letter and the fitter cannot find the part; where the same code serves several devices note which (KM1 of =A-P101) to avoid mix; write current values (rated, set) not design values; number the fix steps and make them checkable so the field stays ordered; bind the manual revision to the drawing revision, issue on revise and recall the old.
| Entry | Content | Point |
|---|---|---|
| By code | KM1 one | Fast search |
| Fault tree | Symptom to code | Check pull |
| Double locate | Sheet plus cab | Drawing hardware |
| Spare | Spare no | Direct buy |
| Consistent | With live | No wrong part |
| Revision | Bind drawing | Issue sync |
Rule: in the manual build one entry per component code (KM1 with function, parameters, faults, fix), pair a fault tree from symptom to code, attach sheet coordinate and cabinet location for double locating, mark spare numbers, add a QR link to drawing and BOM; keep code identical to live hardware, note which device for repeated codes, write current values, number steps, and bind revision to the drawing with old recalled.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Documentation per GB/T 6988, item codes per GB/T 5094 (IEC 61346), symbols per GB/T 4728. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.