Knowledge Base › Electrical Knowledge Base › Applying wire numbering to assembled equipment sets
HomeModels
Table of contents

On this page

Electrical Control & Drawings (500 articles)

Quick Reference

Applying wire numbering to assembled equipment sets

A set of dozens of cabinets and racks turns three-digit wire numbers into a dead end unless cabinet and rack identifiers join the number. This page extends wire numbering for complete sets.

1. How it works

Single cabinets survive on three digits; equipment sets (MCC line-ups, distribution rows, production-line cabinet groups) need prefixes: cabinet plus wire, e.g. A03-112 for row A cabinet 3 wire 112, extended with a rack level (A03-R2-112) and a box identifier between the PLC cabinet and field junction boxes. Rules are project-wide, stated on the first sheet of the system drawings, and consistent with the device numbering in the cable schedules, so the prefix alone locates the cabinet and rack.

2. Practice and pitfalls

Cross-cabinet wires (ties, fieldbus, interlocks) get their own interface block (say from 900) and pair with the cable schedule: cores of cable W315 land in each cabinet under its own block. EPLAN-class tools generate the full number from structure identifiers (row, cabinet, rack). Trap: using each cabinet internal number at both ends duplicates numbers across cabinets and defeats tracing. Control it: issue a numbering rules document first, all parties follow it, site never renumbers, hang the cabinet tag in every drawing header, sleeve temporary commissioning jumpers marked temporary and remove them at handover, and archive the final wire table per cabinet.

3. Set-level wire number structure

LevelExampleNote
RowARow prefix
CabinetA03Cabinet prefix
RackR2Rack level
Wire112In-cab block
Interface900 upCross-cab
TempTemp tagRemove later

4. Notes

Extend wire numbers with row, cabinet and rack prefixes (A03-R2-112) under one project-wide rule stated in the system drawings. Cross-cabinet wires use a dedicated interface block tied to the cable schedule, and structure identifiers generate numbers automatically. Issue the rules first, follow them everywhere, tag temporary jumpers and archive final tables per cabinet.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Documents per GB/T 6988, tagging per IEC 81346, terminal marking per GB/T 4026. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Internal numbers at both ends duplicate across cabinets
② Parties ignoring the rules split the system
③ Untagged temporary jumpers leave rogue numbers

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.

Related reading

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Electrical Knowledge Base · free self-study reference for electrical & automation engineers, 3D CAD models at MOULDL