Each stage of a project needs its own drawing types; mismatching them wastes effort. This page maps drawing types to stages from concept to as-built so the drawing plan lands right the first time.
The correspondence runs: concept stage uses system and overview diagrams to fix the supply structure and main equipment for scheme review; preliminary design deepens them and adds main schematics to settle the control scheme and equipment list; construction design issues the full set, schematic, wiring, terminal schedule, layout and installation drawings, directly guiding the build; completion issues the as-built set folding in every change. The classic mismatch: wiring-level detail at concept review, where nobody reads it.
Depth advances with stage: concept at equipment level, one page telling the structure; construction at terminal level, every wire accounted for; as-built at construction depth plus change records. Too shallow shows as site crews idling for a missing terminal schedule; too deep shows as concept reviews turning into read-alouds. Give each stage a drawing list and depth standard, and task designers from that list.
A drawing plan lists types, quantities and delivery nodes: concept drawings with the scheme review, construction drawings after cross-discipline sign-off, as-built with the acceptance file. The plan tells the site which sheet to wait for and when, cutting idle time. Stage changes accordingly: changes during construction must assess what is already built, while as-built changes are pure re-issue and archive. Roll the plan with weekly project reports.
| Stage | Main drawings | Depth | Delivered to |
|---|---|---|---|
| Concept | System, overview | Equipment level | Review board |
| Preliminary design | System plus main schematics | Loop level | Design review |
| Construction design | Schematic, wiring, layout, installation | Terminal level | Contractor |
| Construction support | Change drawings | In step with work | Contractor |
| Acceptance | As-built set | Construction plus changes | Owner archive |
| Operation | Drawing archive | Matching hardware | Maintenance crews |
Mapping types to stages is the backbone of design management: lay out the drawing plan at kickoff and deliver by list. Two checks tell whether project drawings are healthy: does the current stage have all its sheets, and do delivered sheets reach the required depth; keep both true and the drawing side stays controllable.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Stage division and depth of design documents follow the applicable design documentation codes; drawing classification per GB/T 6988.1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.