The worst failure on a multi-station line is wrong order: the next station fires before the workpiece arrives, and dies crash or parts jam. This page shows how to land sequential control on real lines — sensing, interlocking, and single versus linked mode switching.
Every station gets a presence sensor — limit switch, proximity or photoelectric — wired in series with the next station start circuit: SQ1 closed means station 2 is licensed. Process order is then enforced by workpiece position, not by which button the operator presses first. Choose IP67 metal housings, brace the mounting brackets and shield the sensors against swarf that fakes a signal.
Keep single-station start and stop for maintenance and add a selector SA: in single mode stations run independently; in linked mode the first station launches a cascade that releases each station in turn. A typical cycle is load 2 s, press 3 s, assemble 5 s, each completion signal relayed by KA to the next station. If a station stops with a fault, upstream stations finish the current cycle and pause — no pile, no crash.
Land it in three steps: draw the timing diagram and decide which signals interlock; build the circuit with series interlocks, parallel completion seals and the E-stop at the head of the common bus; and fit a covered, tagged maintenance bypass switch across each sensor so one stuck station can be trialed alone. Never leave a bypass in during production.
| Station | Presence sensing | Interlock condition |
|---|---|---|
| Loading | through-beam photo sensor | part present before press may start |
| Pressing | limit switch SQ2 | slide at top plus SQ1 part |
| Assembly | proximity switch SQ3 | press done plus part present |
| Inspection | fiber sensor | assembly done plus head home |
| Unloading | photo sensor SQ5 | pass signal closed |
Acceptance: press the next-station start with no part and nothing may move; hit E-stop mid-cycle and, after reset, the line resumes from the paused station without repeating finished steps. Then hand it to the operators.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Safety controls per GB/T 16855.1, electrical safety per IEC 60204-1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.