When reversal shock burns contacts, adding a reverse delay is the cheapest and fastest improvement. This article presents three ways: the timer scheme, the off-delay scheme and mechanical options plus the inverter zero-Hz dead band, with wiring effort, cost and suitable applications for each.
The most common scheme: add one timer KT to the control circuit and route the reverse contactor KM2 start path through a KT on-delay contact. Pressing reverse drops KM1 at once, KT times, and after the setting KT closes to pick up KM2. The change is small, a coil and two contacts, tens of yuan, fitting any relay circuit. Do wire the KT instantaneous NC into the forward branch as interlock against a false forward start during the wait.
The off-delay variant uses a KT off-delay opening contact: when KM1 releases the timer starts, its contact stays open locking reverse for the delay, then resets to allow reverse start, so the reverse command may be pre-pressed and the sequence joins automatically. Mechanical options suit those avoiding circuit changes: a delayed mechanical interlock kit or damping on the mechanism, reliable but with fixed, non-adjustable delay, unsuitable for high-inertia machines. On inverter-fed drives, set the zero-Hz dead-band parameter so reverse output only starts after frequency reaches zero, software-level delay with no extra parts. Commission all schemes the same way: no-load sequence check, stop the forward command immediately on pressing reverse, reverse output only after the delay; stopwatch the real delay against the setting; then watch the reduced inrush under load. Set the delay at about 1.2 times the coast-down time and archive the parameters.
| Scheme | Effort | Suitable case |
|---|---|---|
| On-delay KT | Coil plus two contacts | Any relay circuit |
| Off-delay KT | Similar change | Pre-pressed commands |
| Mechanical delay | No circuit change | Low-inertia machines |
| Inverter dead band | Parameter only | Drive retrofits |
| Verification | No-load plus timing | Mandatory for all |
A reverse delay removes plug-reverse shock at its source: a tens-of-yuan timer buys double contact life and spares the gearbox. After fitting, verify the sequence no-load and time the delay, archive the settings; and never let the delay replace the interlock, they stack rather than substitute.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: See GB 14048.4 and GB 14048.5 for apparatus, GB/T 5226.1 for machinery safety, IEC 60947-5-1 and IEC 60204-1 for reference. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.