A crane needs start-stop and e-stop from cab, floor and remote, the classic battlefield of multi-point control. This note covers how to lay it out, how e-stop series-wires a double chain, and how inching and speed change parallel, against GB 6067.
A crane has at least cab, floor pendant and wireless remote, sometimes a maintenance platform. All start and inch buttons parallel, all stop and e-stop series back to the main contactor and each mechanism contactor. Cab and floor stop chains are series together, so any e-stop releases the main contactor and kills all power. Control voltage is usually 36 V safety extra-low voltage per GB 6067 and GB/T 5226.1 to prevent shock.
Safety hinges on e-stop and zero position. Each e-stop is series in the main stop chain and mechanically linked to the main contactor, pressed it must cut main power. Zero-position protection requires each controller at zero before start, preventing sudden motion on power restore; its contact also series in the start branch so any handle off zero cannot start. Inching buttons parallel across the hold for non-latching, speed buttons switch resistance or drive gear. All e-stops stay hard-wired series even on wireless, safety never relying on the signal. Acceptance tests every point start-stop and every e-stop cutting main power.
| Point | Control | Safety | Standard |
|---|---|---|---|
| Cab | Start speed | E-stop main | GB 6067 |
| Floor | Start e-stop | In chain | GB/T 5226.1 |
| Remote | Command | Wired stop | SELV |
| Zero | Zero protect | In start | No false |
| Voltage | 36V SELV | Anti shock | GB 6067 |
| Accept | Per point | Cut main | Sign |
The core of crane multi-point control is any point cutting main power in emergency, e-stop hard series, zero protection in start, 36 V safety voltage. Wireless e-stop stays wired, safety independent of signal. Accept per point and per e-stop cutting main.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Crane safety per GB 6067, control per GB/T 5226.1 and IEC 60204-1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.