Symbols and Physical Counterparts of Common Motor Control Components

Not recognising symbols on the drawing or matching parts on the cabinet is the biggest hurdle for newcomers. This article pairs national-standard symbols with real components used in motor control.

1. How it works

Contactor KM: the symbol is a box with text, main contacts thick, auxiliary thin; the physical part is a magnetic switch with arc chute, main contacts in the power circuit and auxiliary in control. Thermal relay FR: symbol is a rectangle heater plus normally-closed contact; the physical bimetal sits in the main circuit and its NC contact in control for overload cut. Breaker QF: symbol is a box with X, the physical modular switch combining isolation, short-circuit and overload. Buttons SB, fuse FU, timer KT and intermediate relay KA each have standard symbols matching the parts.

2. Practice and pitfalls

Reading tips: the standard uses one text symbol for a device spread across circuits, so coil and contacts share the code (KM coil and KM contacts are one family). Graphical symbols follow GB/T 4728, letter symbols GB/T 7159 (KM contactor, KT timer, SB button, FR thermal, QF breaker, M motor). On the drawing first find motor M and contactor main contacts in the main circuit, then follow the control circuit to the coil and buttons, and map them one by one to the cabinet; symbols and parts then connect.

3. Component Symbol Table

ComponentCodePhysical
ContactorKMArc switch
ThermalFRBimetal
BreakerQFModular
ButtonSBRed/green
TimerKTDelay
MotorMDriven

4. Notes

Common motor control symbols and parts: KM contactor, FR thermal, QF breaker, SB button, KT timer, M motor, all per GB/T 4728 graphics and GB/T 7159 letters. Recognise the family by unified code, separate main and auxiliary contacts, and practise symbol-to-part mapping; a reference card lets newcomers identify and wire correctly.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Electrical drawings see GB/T 4728 (graphics), letter symbols see GB/T 7159, safety see GB/T 5226.1 (IEC 60204-1), low-voltage apparatus see GB/T 14048 series. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Code not uniform: draw part mismatch
② Non-standard symbol: newcomer lost
③ Main aux mixed: wrong wiring

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.

Related reading

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Electrical Knowledge Base · free self-study reference for electrical & automation engineers, 3D CAD models at MOULDL