Some save effort by adding a latch across the jog button so a press keeps running, but the logic breaks. This page analyzes that wrong wiring and why a jog button should never self-hold.
Correct jog is a normally open button SB alone in series before the coil. The wrong way parallels a contactor NO auxiliary across SB, intending press to hold. The moment SB is pressed KM pulls in and that parallel contact closes, shorting SB; after release current flows through the aux contact and the motor keeps running, so jog becomes latch and will not stop on release.
Jog means no memory, run only while held; it relies on the button physically opening to cut the loop. Any parallel hold contact gives the loop a keep channel, and releasing the button just switches current to the aux contact, remembering run state. So a pure jog loop must break on release; any parallel hold destroys it. Use a proper jog-plus-continuous circuit with a selector if both are needed.
| Error | Sign | Result |
|---|---|---|
| SB parallel latch | no stop on release | becomes latch |
| Latched button | press holds | loses jog |
| Tool setting | keeps spinning | hits tool |
| Single stroke | repeats | accident |
| Fix | single NO for jog | no parallel |
| Combined | selector split | jog+run |
Keep the jog button a bare NO in series and never parallel a latch across it. When holding is needed use proper latching or combined control, not a hacked jog button. Any jog that keeps running after release is miswired.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Control safety follows GB/T 5226.1 with IEC 60204-1; buttons follow JIS C 4520. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.