MOULDLKnowledge BaseElectrical Knowledge Base3D Model DownloadsMembership
中文版Model Store »
Knowledge Base › Electrical Knowledge Base › Terminal strip marking sleeves: sizes and printing rules
HomeModels
Table of contents

On this page

Electrical Control & Drawings (500 articles)

Quick Reference

Terminal strip marking sleeves: sizes and printing rules

What size to print, which sleeve to fit, whether to add a strip plate: small things until the print fades and tracing goes blind. This page covers sleeve selection, printing rules and strip plates.

1. How it works

Strip marking has three layers: terminal marker strips clipped on top of the block (ZDU-type, one cell per position), wire number sleeves printed and slipped over the conductors, and a strip plate naming the strip and its function. Buy marker strips matched to the block type; universal adhesive strips must match the width so the print stays fully visible. Letters of 2 mm or larger, readable at 0.5 m, count as qualified.

2. Practice and pitfalls

Print only with a heat-shrink or dedicated marker printer, never handwriting, whose ink fades within half a year. Choose heat-shrink sleeves (no slipping under strain) or semi-rigid PVC, letters facing outward in one uniform direction. Print three elements: wire number, destination device tag, and optionally the loop function (24V+). Keep font and format uniform per cabinet, e.g. always W101-3 style; light background with dark print reads even by torchlight deep in the cabinet.

3. Marking configuration table

LayerFormRule
Marker stripOn block topFont ≥2 mm
Wire sleeveBoth wire ends5 mm from term
Strip plateLaser engravedStrip and function
PrintingMarker printerNo handwrite
DirectionOutwardUniform
Spare holesPre-printed spareNo misuse

4. Notes

Three marking layers: marker strips at 2 mm or larger, wire sleeves on both ends 5 mm from the terminal, and a laser-engraved strip plate naming the strip. Always machine-printed, uniform font and format, letters outward. Verify prints against the list before fitting, and cut off old sleeves when rewiring.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Terminal marking per GB/T 4026, documents per GB/T 6988. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Handwritten sleeves fade within a year
② Wrong strip width hides the print
③ Rewiring without new sleeves mixes numbers

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.