Most actions on an automated line simply follow a timetable: start first, wait a few seconds, then trigger the next step. This page walks through conveyor staging, packaging machine timing and paint-line dwell as three practical patterns, with selection, setting and troubleshooting in one place.
Long conveyor systems start in stages to limit the inrush on the supply: belt one starts, three to five seconds later belt two follows, and so on. Across five sections the peak demand drops to roughly one third of a simultaneous start, using four power-on-delay timers cascaded from one another. Loaded belts need the heavier calculation: stretch the stage delay above five seconds and verify the thermal relays are set for the loaded current, not the no-load figure.
Packaging machines run short confirmations, half a second between feed detection and seal, another second to the cutter, best served by electronic timers on a 0.1 to 10s range within five percent accuracy. Paint lines need long dwell of fifteen to thirty minutes in the drying tunnel, plus a ten-minute exhaust overrun to clear solvent vapour, which suits digital timers or delay modules. The dividing line between the two is range and precision: pick electronic types for short stages, digital types for long ones.
Three faults dominate: a stage that never starts, where you first measure whether its timer fired; drifting sequence, usually dust in an air-damped timer, cured by switching to electronic; and misaligned restart after an emergency stop, because timers had not fully reset, cured by wiring reset confirmation or a two-second restart lockout.
| Application | Purpose of delay | Typical setting | Selection advice |
|---|---|---|---|
| Conveyor staged start | Spread starting current | 3~5s per section | Cascaded power-on-delay timers |
| Packaging seal and cut | Confirm and link steps | 0.5~1s | Electronic type, 0.1~10s range |
| Drying tunnel dwell | Hold process temperature | 15~30min | Digital timer or delay module |
| Exhaust fan overrun | Clear heat and vapour | 10min | Digital type, separate reset |
| Restart lock after e-stop | Let stages reset | 2s | One power-off-delay timer |
| Intermittent lubrication | Run and rest cycle | 5min run, 10min stop | Two cycling timers interlocked |
Match the scene first, then choose model and setting. On automated lines stability beats precision: air-damped timers are cheap but drift, and any stage that affects cycle time or safety is usually converted to electronic or digital within a year of commissioning.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Interlock and timing requirements follow GB/T 5226.1 (IEC 60204-1); timer selection refers to the GB/T 14598 series. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.