One sheet cannot hold the whole system, so cross page links use interrupted wires (break symbols) to connect. Draw them wrong and the two pages do not meet, equal to an open circuit. Here are the representation and connection rules for interrupted wires.
Rule one: when one signal ends on a page and continues on another, draw an interrupted wire symbol (small slash or break box) at both ends, labelled inside with the code and destination page (KM1 to 3 means go to page 3). Rule two: they come in pairs, the start and end interrupted wires match code and page, one check and they align. Rule three: label the signal name or wire number beside the break, not just a symbol. Rule four: common networks like supply or ground may run continuously or use net labels, no need to break every page. Rule five: keep break direction clear, avoid flipping up and down and reversing the connection.
Rules and check: rule six, one interrupted wire code is globally unique, no duplicate no miss, or pages connect wrong; rule seven, the page number must really exist and be correct, pointing to a wrong page equals open circuit; rule eight, change one end and change both ends in sync, updating page numbers together; rule nine, after output run an interrupted wire consistency check listing all pairs to verify pages; rule ten, the drawing contents notes each page theme to jump fast with breaks; rule eleven, on revision the break mapping updates too.
| Rule | Do | Use |
|---|---|---|
| Pair | Both ends | Correspond |
| Label | Code page | Where to |
| Unique | Global no dup | No wrong |
| Real page | Exists | No open |
| Sync | Both ends | Consistent |
| Check | Consistency | Run verify |
Rule: draw interrupted wires at both ends of a cross page signal (break box or slash) with code and destination page (KM1 to 3), appearing in pairs that correspond; code globally unique, page really exists, drawing only one end or wrong page number both cause open circuit; change both ends in sync, run consistency check after output, contents notes themes, so the wire breaks but the signal does not.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Electrical documentation per GB/T 6988 series, symbols per GB/T 4728, item codes per GB/T 5094. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.