Solenoid valve and electromagnet symbols on electrical drawings

Solenoid valves and electromagnets are both coil driven, but their symbols follow different standards. This page explains how electromagnets and directional control solenoid valves are drawn on the electrical side and where the fluid symbols belong.

1. How it works

An electromagnet (YA) is drawn as the usual coil rectangle plus an actuator qualifier showing what it drives: an arrowed rod for linear motion, a sector for rotary motion. It converts electrical energy into mechanical force, so the direction of action must appear on the drawing or nobody knows which way it pushes. Annotate coil voltage and current, for example 24V DC.

2. Practice and pitfalls

A solenoid valve is a coil controlling a spool, and the drawing splits into two layers: the electrical sheet shows the coil YV with its control contacts, while the fluid path is drawn per GB/T 786 (fluid power symbols) as valve boxes on the hydraulic or pneumatic sheet. The two sheets share the same code YV1 for correlation. Drawing the fluid valve boxes inside the electrical schematic mixes languages and confuses everyone; the electrical sheet keeps only the coil and contacts, and the valve paths live on the system drawing.

3. Solenoid valve and electromagnet symbol table

DeviceElectrical symbolLetter codeMarking points
Electromagnetcoil plus push rodYAvoltage and action direction
Solenoid valve coilrectangleYVvoltage and ports
Directional valve (fluid)valve boxesYV on other sheetdrawn per GB/T 786
Proportional valvevalve plus slashYVcontrol signal marked
Magnetic clutchcoil plus discYCvoltage marked

4. Notes

Draw the electromagnet as coil plus actuator mark, and keep the solenoid valve electrical sheet to coil and contacts only with the valve paths on the fluid drawing. Voltage and port codes must be explicit, the codes must match the hydraulic sheet, and never add electrical contacts to a solenoid valve that has none.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Electromagnetic actuators per GB/T 4728.7; fluid power symbols per GB/T 786 and ISO 1219. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Electromagnet coil without voltage marked: 220V wired onto a 24V coil burns it on the spot
② Valve code not matching the fluid drawing: maintenance cannot find the right valve
③ Solenoid valve drawn with contacts like a relay: the device has no electrical contacts, status comes only from position sensors

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.