Pushbutton colors are not a matter of taste; the standard spells them out. This page covers what red, green, black, white, blue and yellow each mean, the special requirements on emergency-stop buttons, and how to pick contact combinations by function.
Under GB/T 5226.1 marking rules: red belongs exclusively to stop and emergency stop, and any red press must result in stopping, no other duty; green belongs to start; black covers other actuations such as jog, reset and confirm; white or gray serves auxiliary functions without special meaning; blue marks standby functions requiring reset, like alarm acknowledgment; yellow marks intervention on abnormal conditions. A button that both starts and stops must carry dual marking. The field violations are predictable, red buttons used for jog, green for reset, and they train operators into reflexes that misfire exactly when it matters. Color discipline is safety discipline.
Emergency-stop requirements: mushroom head, press-to-latch with twist or key release, red mushroom on a yellow base; always normally-closed contacts so a broken wire and a press both read as stop; prominent size within one step of every operating position, at least one per station and distributed along long lines; contacts wired in series into a safety relay or straight into the contactor coils. E-stop never passes through the PLC for its protective action, hardwired only. Reset is not restart: after releasing the e-stop the machine must not self-start, a deliberate start press is required so nobody is still in the danger zone. Quarterly, press every e-stop in turn and confirm the corresponding equipment all stops and demands a manual restart.
Contact combinations follow function: start uses NO momentary with contactor latching; stop uses NC for fail-safety; composite buttons, one NO one NC, fit interlock duty where the break-before-make mechanical sequence matches changeover logic; illuminated buttons merge operation and status with the lamp wired across contactor contacts for truth; key buttons guard authorized operations. Mind contact ratings, especially breaking inductive loads, and environment: IP65 plus covers in oily or wet shops, larger caps for high-frequency operation. Leave at least fifty millimeters between adjacent button centers so gloved hands cannot press two at once.
| Function | Color | Contact type | Basis |
|---|---|---|---|
| Start | Green | NO | GB/T 5226.1 |
| Stop and e-stop | Red mushroom | NC, latching | GB/T 5226.1 |
| Jog and auxiliary | Black or white | NO | As needed |
| Alarm acknowledgment | Blue | NO | Standby reset |
| Abnormal intervention | Yellow | Per function | Intervention duty |
| Interlocked switching | Composite | One NO one NC | Break before make |
Align color and contacts to function from this table in design and retrofit alike. Two bottom lines: red means stop only, and the e-stop breaks without restarting. Color is the operator signal language, and a panel that speaks it confusedly multiplies wrong presses in emergencies, which makes this a safety issue, not an aesthetic one.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Color identification and marking of actuation devices follow GB/T 5226.1 (IEC 60204-1 clause 10); pushbutton switch requirements follow GB/T 14048.5. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.