One small motor tripping can idle the whole line at a loss bigger than the fault itself, and that stopping range is a design output. This page analyzes how a single fault propagates along the interlock chain, how to calculate the stopping range, and how to narrow it sensibly.
Propagation works on two layers. Electrically, the thermal NC contact feeds the downstream control circuits, so the stop signal walks the interlock chain and downstream machines lose their run conditions in turn. Process-wise, even if the downstream were left energized, continuing to run without upstream feed causes pileups, dry burning and dry grinding, so the process demands the stop anyway. The two layers together mean the stopping range must be designed electrically and process-wise at once. Propagation is unidirectional: upstream machines usually survive a downstream fault, but stop-interlocks can pull upstream machines down where their operation depends on the downstream, as when a conveyor stops and the silo screw would pile material unless it stops too.
Calculate the range in three steps. Draw the interlock topology, one node per machine, arrows for dependencies. Play through every machine trip, following the arrows to the downstream stop set, and compare it with the process-allowed set. Hunt unintended propagation, especially two cases: stop-interlock contacts dragging an upstream machine down unexpectedly, and what the downstream does when a timer link fails, immediate stop or no stop. Record the results as truth tables and simulate each row before commissioning. Over-stopping (machines halted that the process could keep running) and under-stopping (machines left running that should have stopped) both call for wiring or interlock corrections.
Four tools narrow the range: parallel redundancy, doubling critical upstream machines so one trip leaves the other feeding; buffer decoupling, an intermediate hopper whose level, not the upstream run status, governs the downstream interlock, stopping only below the low level; graded interlocking, converting hard stops to confirmed or delayed ones, as in spindle coast-down; and degraded modes, a partial-coordination state at half production instead of a full stop. Narrowing never touches safety interlocks, guard switches and e-stops stay absolute, and every narrowing scheme needs joint review with process and safety engineers.
| Faulty station | Electrical stop range | Process impact | Narrowing tool |
|---|---|---|---|
| M1 pump overload | M1 M2 M3 all stop | Spindle loses lubrication | Dual-pump redundancy |
| M2 conveyor overload | M2 and M3 stop | Downstream starves | Hopper decoupling |
| M3 main motor overload | Only M3 | Upstream runs idle | Delayed or held upstream stop |
| E-stop pressed | Whole line, instant | Process interrupt | Never narrowed, safety first |
| Guard opened | Related machines stop | Work interrupt | Safety interlock, no narrowing |
| KT link failure | Downstream stops at once or not | Sequence breaks | Regular KT verification |
Trace stopping range and narrowing tool per faulty station at design review and fault analysis alike. The golden standard: machines that must stop always stop, machines that could keep running are not stopped needlessly, and when the two conflict safety wins, with safety interlocks excluded from any narrowing forever.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Safety interlock and stopping functions follow GB/T 5226.1 (IEC 60204-1); overload protection coordination refers to GB/T 14048.4. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.