Time relays come as air-dashpot and electronic, prices and life far apart; wrong choice mistimes the field. This note compares five dimensions, accuracy, life, environment, price, adjustment, to pick right from appliance to industrial without waste or failure.
Air-dashpot delays by bellows air in and out, low accuracy to twenty percent, affected by temperature and pressure, but extremely interference-proof, immune to electromagnetic noise, cheap. Electronic delays by RC or crystal, high accuracy one to five percent, stable, digital set, but sensitive to supply swing and strong interference, several times pricier. Accuracy need is the first divide: rough delay like cooling tens of seconds, air suffices; precise like sequence interval, electronic.
Life electronic no mechanical wear, electrical life million, maintenance-free; air has diaphragm and spring ageing, tens to hundred thousand then replace. Environment air fears dust and moisture, hole blocked; electronic fears high temperature humidity and strong EM, needs shield. Price air tens of yuan, electronic hundreds. Choose: harsh EM, rough delay, cost-sensitive use air; clean, precise, frequent, remote-set use electronic. Adjustment: air screw and stopwatch, scale coarse must calibrate; electronic digital set accurate but still stopwatch spot-check drift. Maintain by environment: dusty moist shorter air check; strong interference electronic shield filter. Critical equipment prefer electronic with spare, ordinary air economic durable. Accept both with stopwatch for direction and value, not nominal.
| Dimension | Air | Electronic |
|---|---|---|
| Accuracy | +/-20% | +/-1-5% |
| Life | Tens k | Million |
| Env | Dust moist | Noise temp |
| Price | Tens | Hundreds |
| Adjust | Screw watch | Digital |
| Choose | Rough cheap | Precise freq |
Air accuracy low plus minus 20 percent, interference-proof, cheap, life tens thousand, for rough delay harsh EM; electronic high plus minus 1 to 5 percent, life million, noise temp sensitive, several times cost, for precise frequent clean. Accept both stopwatch direction value not nominal.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Timer selection per GB/T 5226.1 and GB/T 14048.5, IEC 60204-1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.