Drawings for export fail review when symbol systems, letter codes and annotations clash with customer habits. This page explains how GB/T 4728 relates to IEC 60617, how to adapt markings for overseas projects, and what to deliver so the customer can review without guesswork.

1. How it works

GB/T 4728 was adopted from IEC 60617, so the common symbols match across both systems, which is a real advantage on export jobs. Watch the differences: letter codes follow GB/T 7159 at home with KM, FR and QF, while European projects often use IEC 81346 codes such as -Q1 and -K2; terminal marks written X1:1 domestically appear as U1 V1 W1 or plain numbers on European sheets. Confirm the symbol standard with the customer first and state the chosen system on the front page.

2. Numbers and practice

Bilingual annotation is the common practice: title blocks and technical requirements in Chinese and English, letter codes kept with English descriptions such as KM1 contactor. Use SI units throughout, write conductor sizes as mm2 rather than in Chinese characters, and set voltages to the destination grid, typically 400V/230V instead of 380V/220V. Check paper size preference too, A0 to A4 versus letter and ANSI, along with date formats, before issuing.

3. Pitfalls and fixes

Before delivery do three things: a declaration page listing the GB/T and IEC symbols used; a legend page collecting every symbol in the project for the customer to review; and a bilingual glossary so contactor and starter are not mixed for the same device. Log every review comment, and when a symbol changes assess the impact across the whole set so schematic and wiring diagrams stay consistent.

4. Marking differences between domestic and export drawings

ItemDomestic habitExport adaptationNote
Symbol standardGB/T 4728IEC 60617 equivalentState version on page one
Letter codesKM/FR/QFIEC 81346 codesFor example -Q1, -K2
Terminal marksX1:1U1 V1 W1 or numbersConfirm with customer
Grid voltage380V/220V400V/230VFollow destination grid
Paper sizeA0 to A4letter/ANSI optionalAsk the customer
LanguageChineseBilingualUnified by glossary

5. Notes

Misunderstanding is the real cost on export jobs; a legend page and a glossary are cheaper than weeks of translation ping-pong. Build a company export template with the declaration, bilingual title block and glossary fixed as standing pages, and each project only fills in content.

6. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Symbol cross-reference per GB/T 4728 and IEC 60617; marking systems per IEC 81346. Always check the device datasheet and the product design file for ratings and derating.

7. Cautions

⚠️ Three common pitfalls:
① Chinese-only annotations block customer review and burn weeks on translation loops
② Writing 380V for a 400V grid shifts device sizing and protection settings everywhere
③ Changing a symbol without checking the whole set leaves schematic and wiring versions in conflict

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.