Wiring the reciprocating circuit is only the start; if the switch and cam positions are off, the table overruns or stops early. This note covers how to set the position: fix travel first then cam, find the repeat dead band by trial runs, and stabilise repeat accuracy with veteran tricks.
Before adjusting, measure the needed effective travel and mark the left and right end positions on the rail. Rough-mount the cams near the ends, mount the switch on the cam path with roller facing it. Manually or by jogging bring the table near the end, check the switch is pressed with enough overtravel, typically 2 to 5 mm. Too little overtravel misfires on vibration, too much actuates early. Rough then fine, do not rush to perfect in one move.
Fine-tune by trial: run the table back and forth ten times and watch the stop-position scatter at each end. If scatter is several millimetres the cam or switch is loose or there is mechanical backlash; tighten the cam, remove screw backlash until scatter under 1 mm. Also check the switch resets crisply; a spring-back cam with too much rebound chatters start-stop. Accuracy needs both mechanical and electrical tuning. Tips: use adjustable screw cams for easy micro-adjust, switches with adjustable roller arm, end deceleration in PLC to cut overshoot, monthly re-tightening on vibrating machines, and 1 to 2 mm safe gap between switch and cam.
| Step | Method | Standard | Note |
|---|---|---|---|
| Set travel | Mark rough | 2-5mm | No rush |
| Trial | Ten runs | <1mm | Loose gap |
| Adj cam | Screw | No strip | Torque |
| Adj switch | Arm | Right press | Face cam |
| Decelerate | PLC slow | Less shock | No over |
| Recheck | Monthly | No vib | Gap |
Adjust by fixing travel and rough cam, then ten trial runs with scatter under 1 mm, micro-adjust with screw cam and switch. End deceleration cuts shock, monthly re-tightening prevents loosening, keep 1 to 2 mm safe gap; fast accurate durable.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Position accuracy per GB/T 5226.1, mechanical per GB/T 17421. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.