To stagger multi-machine start and cut grid shock, a time-delay relay sequences the start. This note gives the seven wiring steps and setting method so three motors start in order, not all closing at once and tripping the main switch.
Delayed start logic: first machine starts directly; after it runs, KT1 times and at set point closes the second; after the second runs, KT2 times and closes the third, and so on. Each start signal comes from the previous machine KT delay contact, forming a sequence chain. Each self-locks to keep running, stop is together or separate. The total inrush is stepped, avoiding simultaneous close shock.
Wiring seven steps: lay total supply and total stop chain, all stop buttons series. Step two first machine main and control, start, self-hold, coil. Step three second machine main done, its control start branch has KT1 delay-close contact, on-delay, in series, so only after first runs and delays may second start. Step four KT1 coil paralleled on first contactor auxiliary NO, first start triggers timing. Step five third machine with KT2 same. Step six check diagram. Step seven jog each for direction then test sequence with stopwatch on interval. Set each KT 2 to 5 seconds so the previous inrush peak passes before next; set with knob or dip, coarse then stopwatch calibrate. Accept: simulate total start, see three pick up in order with set interval; drop one see others still sequence; e-stop cuts all; one fault does not break the rest. Debug dead then live, chain then point, retest after each change.
| Step | Content | Point | Order |
|---|---|---|---|
| Chain | Stop series | Safety | First |
| First | Direct start | Self | Second |
| Next | KT delay start | Prev delay | Third |
| KT coil | Par prev NO | Time on | Fourth |
| Check | Wire no | No err | Fifth |
| Accept | Stopwatch | Interval | Sixth |
Delayed start: previous runs then KT delays next, sequence chain, total inrush stepped. Seven steps: chain, first, next KT delay, KT coil par prev NO, check, jog, sequence test. Set 2 to 5 s stopwatch calibrated, accept ordered pick-up and e-stop cut all.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Sequence start and control per GB/T 5226.1 and IEC 60204-1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.