Push buttons are the operator interface of every machine, and a wrongly drawn button turns start into stop. This page explains the standard symbols for normally open, normally closed, combined and illuminated buttons, plus the hexagon frame that marks an emergency stop device.
Per GB/T 4728 a push button is drawn as a small circle containing one contact pair that shows its nature. A start button (SB plus number) shows an open contact, a stop or emergency button shows a closed contact, and a combined button carries both an NO and an NC pair inside the circle. Buttons are momentary devices: the spring returns them on release, so a schematic never shows self-holding at the button itself, and the holding contact is the contactor auxiliary contact wired in parallel.
Special buttons carry qualifying marks. An emergency stop device adds a regular hexagon around the button symbol, a requirement stressed by both GB/T 4728 and the GB 5226.1 safety standard; an illuminated button adds a lamp symbol or letter inside the circle, and a key-operated button carries a key mark. Omitting the hexagon makes the drawing non-compliant, and a combined button drawn with only one contact pair hides a path that must open when the button is pressed.
| Button type | Symbol | Contacts | Typical use |
|---|---|---|---|
| Start button | open contact in circle | NO | green, starts machine |
| Stop button | closed contact in circle | NC | red, stops machine |
| Emergency stop | hexagon plus circle | NC | red, cuts power |
| Combined button | two lines in circle | one NO one NC | jog plus stop |
| Illuminated button | lamp in circle | NO | with status indication |
The hexagon frame on an emergency stop device is a hard safety requirement, and a drawing without it fails review. Record button colour and contact type in the terminal list so the wireman connects green to NO start and red to NC stop instead of reversing the operating logic.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Button symbols per GB/T 4728.7; emergency stop requirements per GB 5226.1 and IEC 60204-1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.