National standard, IEC, old mechanical drawing, each code system has its origin. Taking over equipment from different sources means knowing which standard it uses and how to map between them, or you will fit the wrong hat on the wrong head. Here is the comparison and selection.
Origins: the national standard GB/T 5094 is identical to IEC 61346 and is the main line for domestic electrical item codes, from which the class letters and higher location structure come; IEC 61175 governs the uniqueness rules of reference designations; old drawings may keep old mechanical drawing habits or company defined codes with different letter meanings; foreign brand equipment such as Siemens or ABB often follows IEC 61346 but adds its own prefix. Know the source before assuming KM means contactor.
Compare and select: line up the letter tables of different standards side by side, K equals contactor relay, M equals motor, Q equals switch, align letter by letter and build a comparison table; on taking over old equipment first identify which system it uses, then decide to keep or migrate to GB/T 5094; for new projects always use GB/T 5094 as the main line for readability and maintenance; for mixed equipment build a mapping at the interface noting the two code correspondences; train the team on one standard, no separate styles.
| Standard | Origin | Adopt |
|---|---|---|
| GB/T 5094 | Domestic main | Same as IEC61346 |
| IEC 61175 | Uniqueness | Reference desig |
| Old drawing | Old habit | Identify first |
| Foreign | IEC system | Add prefix |
| New project | Unify | Use 5094 |
| Mixed | Build map | Note interface |
Rule: GB/T 5094 identical to IEC 61346 is the domestic main line for electrical codes (K contactor, M motor, Q switch), IEC 61175 governs uniqueness; on takeover first identify which standard the old or foreign equipment uses and build a letter comparison, use GB/T 5094 for new projects, build interface mapping for mixed equipment, train the team on one standard, and never force fit or invent.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Item codes per GB/T 5094 (identical to IEC 61346), reference designation uniqueness per IEC 61175, symbols per GB/T 4728. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.