MOULDLKnowledge BaseElectrical Knowledge Base3D Model DownloadsMembership
中文版Model Store »
Knowledge Base › Electrical Knowledge Base › Common exam points for graphic symbols in vocational training
HomeModels
Table of contents

On this page

Electrical Control & Drawings (500 articles)

Quick Reference

Common exam points for graphic symbols in vocational training

Electrician training and certification always test symbol reading. This page sorts the common exam points for graphic symbols and the high-frequency losing mistakes.

1. How it works

Point one is recognition: given a symbol, produce the name and letter code, the three-phase motor as M in a circle, the breaker as an X in a box labelled QF, the contactor coil as a rectangle labelled KM, the start button SB, the fuse as a wavy rectangle labelled FU, the thermal relay FR, the time relay KT. Trainees must react instantly from graphic to device, the basis of both written and hands-on tests. High-frequency losses: contactor and relay coils confused, NO and NC symbols reversed.

2. Practice and pitfalls

Point two is reading and error-finding: given a schematic, spot the symbol errors, an emergency stop without the hexagon, contact states reversed, a CT secondary drawn openable, a thermal relay drawn NO, the phase sequence annotated backwards. Also draw the contact types of self-holding and interlocking loops. High-frequency losses: failing to judge contacts from the de-energised state, missing the emergency-stop frame, drawing a solenoid valve with relay contacts. Training should drill on real drawings rather than isolated symbols.

3. Training symbol exam points table

Exam pointContentCommon errorDrill
Recognitiongraphic to name and codecoils confusedflash cards
Contact statejudged from de-energised stateNO and NC reversedtrace through
Error findingspot the symbol mistakesframe omittedread real drawings
Conversionsimplified versus fulllink lostreassemble the device
Hands-onidentify at the cabinetcannot read at alltag symbols on site

4. Notes

Training exam points split into recognition (graphic to name and code), reading and error-finding (emergency-stop frame, contact states, CT open circuit, thermal relay drawn NO, phase sequence), simplified-versus-full conversion and hands-on identification. High-frequency losses are reversed NO and NC, the missing frame and the solenoid valve drawn as a relay. Teach on real drawings, compile past mistakes into a booklet and add an on-site reading stage to the assessment.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Training symbols per GB/T 4728 and GB/T 6988, referenced against the electrician occupational standard. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Isolated symbols memorised only: trainees freeze on a full drawing
② Written test only: still unable to read drawings on the job
③ No mistake booklet: the same errors recur every cohort

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.

Related reading

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Electrical Knowledge Base · free self-study reference for electrical & automation engineers, 3D CAD models at MOULDL