A two-speed motor changes pole count by reconnecting the stator winding, giving two speeds from one machine. This page explains the delta and double-star principle, terminal operations, and the contactor scheme that keeps the two connections safely exclusive.
Synchronous speed follows sixty times frequency divided by pole pairs, so with the 50Hz supply fixed, changing the winding connection changes the speed. Each phase of a two-speed stator is built from two half-windings: in series the pole count doubles and the motor runs slow, about 750 r/min for a four-pole winding; paralleled into a double star the pole count halves and the motor runs at 1500 r/min. The common delta/double-star arrangement is constant-power, suiting fans and pumps whose torque rises with the square of speed; the star/double-star variant is constant-torque with strong low-speed torque.
The terminal box carries six studs, U1V1W1 and U2V2W2. Low speed delta: power on U1V1W1 with U2V2W2 shorted, giving the series connection. High speed double star: power on U2V2W2 with U1V1W1 shorted into the neutral point, giving the parallel connection. The two states must never coexist, or the windings short phase to phase. Use jumper links or contactor contacts: KM1 feeds the delta, KM2 feeds the double star and KM3 makes the shorting. Terminal arrangements differ between manufacturers, so always verify against the nameplate connection diagram before wiring.
The control circuit uses three contactors with electrical interlocks: KM1 versus KM2 and KM3, each pair blocking the other, so only one connection can ever be energized. For heavy loads, start in low speed for five to ten seconds and let a timer switch to high speed automatically; light loads may start directly in high speed. Any change of connection requires a full de-energization first, never a live pole change, which would subject the windings to switching overvoltage and weld the contacts.
| State | Power terminals | Shorted terminals | Contactor action |
|---|---|---|---|
| Low speed delta | U1V1W1 | U2V2W2 shorted | KM1 and KM3 in |
| High speed YY | U2V2W2 | U1V1W1 shorted as neutral | KM2 and KM3 in, KM1 out |
| Stopped | None | None | All released, interlocks reset |
| Low-speed start | U1V1W1 | U2V2W2 | KM1 first, timer runs |
| Auto changeover | Move to U2V2W2 | U1V1W1 | Timer fires, KM1 out, KM2 KM3 in |
| Nameplate check | Per nameplate | Per nameplate | Arrangement varies by maker |
Keep this table beside the terminal box when wiring or troubleshooting. The core discipline is mutual exclusion of the two connections: every interlock contact counts, and any reconnection happens only with the machine dead, verified with a tester before hands touch anything.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Terminal marking and rotation direction follow GB/T 1971; controlgear coordination refers to GB/T 14048.4. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.