How contact quantities are represented in electrical symbols

One device often carries several contact sets, and drawings handle this with simplified and detailed styles. This page explains how multiple contacts are represented, numbered and matched against the real hardware.

1. How it works

Contactors and relays frequently carry multiple contact sets. GB/T 4728 assigns them the same letter code with suffixes: the main contacts of KM1, its NO auxiliary KM1-1 and its NC auxiliary KM1-2. A simplified drawing shows only the coil, and every contact scattered elsewhere on the sheet carries the same code; a detailed drawing spells out every contact set with its number. Readers regroup the scattered contacts into one device by the code, and the material list states the contact configuration, for example a CJX2 contactor with 1 NO and 1 NC auxiliary.

2. Practice and pitfalls

The quantity rule is strict: state the configuration beside the device, such as 3 NO plus 2 NC, or list the contacts in a small table; some practice allows NO1, NC1 labels beside the symbols. The drawn quantity must equal the hardware: three contact sets drawn against two real ones leave the third set unconnected, and a real set missing from the drawing loses its function silently. Copy the contact configuration straight from the selection catalogue when drawing.

3. Contact quantity notation table

DeviceContact configurationCode notationCaution
Contactor3 main, 1 NO, 1 NCKM1 main, KM1-1match the hardware
Intermediate relay4 NO, 4 NCKA1 with suffixesnot two devices
Time relaydelayed NO and NCKT1 with arcsdelay direction
Push button1 NO or 1 NCSB with numbercombined has both
Limit switch1 NO, 1 NCSQ with suffixesmechanically actuated

4. Notes

Multiple contacts of one device share the code with suffixes, and simplified drawings regroup coil plus scattered contacts by that code. The drawn contact quantity must match the selection catalogue exactly, with NO and NC counts not swapped, otherwise self-holding and interlocking logic come out wrong.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Multi-contact notation per GB/T 4728.7; device contact configurations per GB/T 14048 and IEC 60947 series. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Auxiliary contact labelled with a different code: the self-holding loop cannot close
② More contacts drawn than the hardware has: temporary rewiring on site in a rush
③ NO and NC counts swapped: interlocking turns into self-holding

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.