Cascaded belt conveyors must start and stop in order or the tail piles up and reverse spills. This article covers design: start front-to-back reverse, stop back-to-front, add delay to avoid pile, add slip and pull-cord protection.
Belt line start must go from the last (receiving) stage forward to the first, and stop from the first (feeding) stage backward to the last - opposite to a normal line, so the receiver runs before material is fed, avoiding tail pile. Design uses rear NO as front start permit and front NO locking rear stop, opposite directions.
Each belt needs a 3 to 5 s gap; start the next only after the previous reaches speed, avoiding simultaneous current and mechanical shock. Use on-delay KT cascade, gap by belt length and speed. Stop likewise reverses stage by stage with delay to prevent material piling during shutdown.
Belts need thermal overload, a slip switch (overspeed/zero-speed protection) and a pull-cord E-stop (line safety). Any slip or pull-cord should linked-stop its upstream and downstream belts to prevent belt tear and injury. Design wires these protection contacts into the relevant control loops with fault indication and local/remote switch.
| Point | Do | Goal | Note |
|---|---|---|---|
| Start dir | last to front | no pile | rev piles |
| Stop dir | front to back | no spill | reverse |
| Delay gap | 3-5s each | buffer | by speed |
| Slip prot | slip switch | no tear | must wire |
| Pull cord | line rope | person safe | must wire |
| Prot inter | in ctrl loop | linked stop | add lamp |
Rule: start last-to-front against pile, stop front-to-back against spill, gap 3-5 s, add thermal slip pull-cord, protections in loop linked stop. Set direction before wiring; wrong direction piles material.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Conveyor per GB/T 5226.1, safety per same. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.