Small and medium machines do not need separate pages: draw the main and control circuits on one sheet in zones, main left and control right. This page explains zoning rules, grid references, weight hierarchy and density control.
Landscape sheets normally zone left and right: the main circuit occupies the left third with busbars running down and motors in a column, while the control circuit fills the right two thirds under a supply busbar across the top. Portrait sheets zone top and bottom in the same spirit. Mark the boundary with a chain line and a zone caption such as main circuit and control circuit, so a reader knows at first glance which territory he is in.
Grid references make single-sheet zoning fast: columns numbered 1, 2, 3 and rows lettered A, B, C give addresses like B2. Put the control zone number beside KM1 main contacts and the main zone number beside the KM1 coil and contacts, and same-sheet references beat cross-page ones. A practical habit is to stack control loops in labelled columns, start column, interlock column, and align each contactor coil with its contacts on a faint chain line so a vertical glance reunites the family.
Guard against two diseases of zoning. Mixing: power lines wandering into the control zone blur the weight hierarchy, so enforce the boundary and let power cross only to motor terminals. Overcrowding: with more than about 60 to 80 control branches on an A3, characters shrink below readability, so step up to A2 or split the sheet. Note the zone legend and line-width standard in the title block, and always check a black-and-white print preview; a drawing nobody can read is waste paper.
| Point | Practice | Parameter | Common trouble |
|---|---|---|---|
| Zoning | Main left or top | Main about one third | Mixed territories |
| Boundary marks | Chain line plus captions | Text 2.5mm and up | Blurry borders |
| Grid references | Row and column crossing | Addresses like B2 | Slow searching without them |
| Family alignment | Coil and contacts in line | Faint chain guide | Families scattered |
| Density control | Branch count ceiling | 60 to 80 per sheet | Unreadable print |
| Weight hierarchy | Thick mains, thin control | 2:1 ratio | Flat hierarchy |
Single-sheet zoning suits medium loop counts: one page holds the whole picture, at the price of density. Count the loops before choosing the sheet size, and step up a frame rather than shrinking text; drawings exist to be read.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Zoning and sheet layout per GB/T 6988.1; grid references per the documentation rules accompanying GB/T 4728. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.