Key points and common errors when checking terminal drawings

A terminal drawing drawn but not checked means the costly rework shows up on site. This page covers what to check and the usual mistakes.

1. How it works

Checking step one is numbers: continuous, no duplicate, no gap, and cross-findable with the wiring wire numbers. Step two is connections: every terminal has a clear destination and cross-page links carry a continuation mark. Step three is marking: earth as PE, shield single-end grounded, jumpers drawn clearly. Any vague item stalls the site. Trap: admiring a tidy drawing but not the logic, then finding two holes share one number.

2. Practice and pitfalls

Six frequent errors: duplicate numbers, missing wire numbers, broken cross-page links, earth terminals mixed in, missing jumper drawings, and no spares. Check against this list tick by tick, then have a second person cross-review and sign before filing; it is ten times cheaper than rework. Use the EPLAN navigator to auto-find duplicates and missing links.

3. Terminal drawing check

PointCheckWrong
NumberNo dupTrace
LinkHas destOpen
MarkPE jumperMiswire
DupSame noShort
CrossContinuedMiss
ReviewTwoOmit

4. Notes

Check that numbers are continuous and cross-findable, links have destinations and marking includes PE and jumpers. Watch six errors: duplicate numbers, missing wire numbers, broken cross-page, mixed earth, missing jumper, no spare. Tick the list, cross-review by two people, re-check after any change and let the navigator find duplicates.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Electrical documentation per GB/T 6988, terminal marking per GB/T 4026. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Duplicate numbers: two holes short
② Missing wire number: terminal only
③ No cross-review: slips through

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.

Related reading

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Electrical Knowledge Base · free self-study reference for electrical & automation engineers, 3D CAD models at MOULDL