A suspended load must not drop on power loss; that is the brake. This page explains how mechanical and electromagnetic brakes lock the shaft and when.
An electromagnetic brake has a disc, spring, coil and lever. De-energised, the spring clamps the shoe on the wheel and locks the shaft; energised, the coil pulls the armature and releases the shoe so the motor turns. This is fail-safe: on power loss it auto-engages, protecting hoists and elevators from dropping. Coils are DC 24/110/220 V, pull-in current 3~5× hold current, fed through a rectifier.
Mechanical brakes such as shoe or band brakes use levers, springs or weights and need no electricity, used on old winches, controlled by handwheel or centrifugal blocks. They never fail on power loss but respond slowly and cannot be remote controlled. Both can fail-safe; the difference is whether release power is electric or mechanical. Hoists must use fail-safe type, never a powered-release brake on a hook.
Adjust three things: shoe gap 0.3~0.8 mm (too big delays engage, too small wears), spring force for torque ≥1.5× static to prevent slip, and interlocking so brake releases before start and engages after stop. Traps: oversized gap lets the load creep down, wrong coil voltage (AC on DC) burns the coil, and no zero-speed interlock wears the brake at low speed.
| Item | Electromagnetic | Mechanical |
|---|---|---|
| Release power | Coil energised | Manual/centrifugal |
| On power loss | Auto engage | Stays engaged |
| Response | Fast <0.5 s | Slow |
| Remote | Yes | No |
| Use | Hoist elevator VFD | Old winch |
Hoists need fail-safe brakes, never powered-release on a hook. Gap 0.3~0.8 mm, torque ≥1.5× static. Interlock brake with motor start/stop at zero speed. Do not miswire coil voltage.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Machinery electrical per GB/T 5226.1; brakes per GB/T 24478. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.