The commutator and brushes are the only parts of a DC motor that rub all day. Proper care buys years of service; neglect produces sparking within months. Four numbers govern the work: pressure, wear limit, undercut depth and surface runout.
Brush spring pressure should sit between 15 and 25kPa with less than 10 percent spread inside one holder, because uneven pressure means uneven current sharing and single-brush overload. Replace brushes worn to one third or one quarter of original height. Seat every new brush with glass-paper drawn against the commutator surface, never carborundum, until at least 70 percent of the face contacts. Mixing brush grades with different resistivity wrecks current distribution and sparks appear the day they are fitted.
A healthy commutator wears a dark brown oxide film that lubricates and conducts; do not polish it away casually. Mica must undercut 0.5 to 1.5mm below the copper, or a proud mica strip holds the brush off the surface and causes high-frequency sparking. Machine the commutator on a lathe when eccentricity exceeds 0.05mm or runout exceeds 0.03mm, and re-undercut afterwards. Blow out carbon dust every two to four weeks with dry air below 0.2MPa, and keep holder temperature under 90C as the daily health indicator.
| Item | Standard | Check tool | If exceeded |
|---|---|---|---|
| brush pressure | 15~25kPa, spread under 10% | spring gauge | adjust or fit constant-force holders |
| brush wear limit | worn to 1/3~1/4 of height | vernier caliper | replace set, same grade |
| mica undercut | 0.5~1.5mm below copper | undercut saw, feeler | re-undercut and chamfer |
| surface runout | no more than 0.03mm | dial gauge | machine on lathe |
| eccentricity | no more than 0.05mm | dial gauge | machine then re-undercut |
| holder to commutator gap | 2~4mm | feeler gauge | reposition holder |
| holder temperature | not above 90C | IR thermometer | check pressure and sharing |
The heart of the work is preserving the oxide film: a motor without sparking does not need surface polishing. Trend spark grade and holder temperature across inspections rather than trusting single readings.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: See GB/T 1311 (DC machine test methods) for maintenance and testing; brush technical conditions per JB/T 2623. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.