UC=U0·e−t/τ: 36.8% at 1τ, 13.5% at 2τ, 5% at 3τ.
Bleeder sizing trades speed against standing loss; mains plugs must fall below safety voltage within 1s per safety rules.
Never short bus capacitors with a screwdriver - use rated discharge resistors and verify with a meter.
| Time | Remaining | Meaning | Example |
|---|---|---|---|
| 0 | 100% | Switch-off | Peak hazard |
| 1τ | 36.8% | Fast decay | Sets the pace |
| 2τ | 13.5% | Near safe | — |
| 3τ | 5.0% | Engineering empty | Common criterion |
| 5τ | 0.7% | Strictly safe | High-voltage work |
| Limit point | Per standard | Touchable plug | t=RC·ln(U0/U) |
Apply the points above to RC discharge; the figures are typical engineering values, so confirm them against the device datasheet and the actual design before release.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Per GB 5226.1, IEC 60204-1, GB 4943.1 and the corresponding IEC documents. Ratings and derating follow the device datasheet and the product design file. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.