Codes like IP54 and IC411 govern protection and cooling; they decide how the motor sheds heat and whether it survives dirt. This page breaks down IP and IC.
IP (Ingress Protection) first two digits: first dust (0~6), second water (0~8), sometimes a third for impact (e.g. K). Common motor ratings IP44/54/55/65. Pick first digit ≥5 for dust, second 4~6 by splash. IP and IC are independent; good protection is not good cooling.
IC (Cooling) code, e.g. IC411: first 4 = surface cooling, 1 = built-in fan (self-cooled), last 1 = free air. Common: IC411 self-fan (most common, motor fan blows the frame), IC410 fanless, IC416 forced independent fan (cools even at VFD low speed), IC01 open natural, IC611 with air cooler. Low-speed VFD must use IC416 or the slow fan starves cooling.
For dusty and forced-cool needs pick IC416+IP55; ordinary shops IC411+IP54; explosive or sealed sites need Ex and matching IC. Traps: a VFD low-speed motor with IC411 gets little fan airflow and overheats, use IC416; reading only IP ignores cooling; an IC410 fanless motor at full load lacks cooling and derates. Rule: IP keeps dirt/water out, IC removes heat; check both.
| Code | Meaning | Use |
|---|---|---|
| IP54 | Dust splash | Ordinary |
| IP55/65 | Jet/wash | Dust wash |
| IC411 | Self-fan | Common |
| IC416 | Forced fan | VFD low |
| IC410 | Fanless | Light small |
IP governs protection, IC governs cooling: IC411 self-fan common, IC416 forced fan for VFD low speed, IC410 fanless only light load. VFD low speed needs IC416 or it overheats. IP and IC are independent; check both.