After rectification the DC is still a pulsating wave. A reservoir capacitor charges on each peak and discharges into the load between peaks, smoothing the output. This page explains the charge and discharge cycle and gives a working formula for ripple voltage.
The capacitor charges through the diode only when the rectified voltage exceeds the capacitor voltage, reaching near the square-root-of-two peak of the AC input. When the diode is reverse biased the capacitor feeds the load, so the voltage sags until the next half cycle tops it up. A larger C or a lighter load, meaning bigger R, gives a slower sag and a smoother rail.
Ripple is roughly delta U equals I load times t divided by C. For 50 Hz full wave rectification t is about 10 ms, so 1 A with 2200 microfarad gives about 4.5 V peak to peak. To push ripple under 1 V at 1 A you need roughly 10000 microfarad. This is the low frequency sag only; capacitor ESR adds a high frequency spike on top, so a low ESR part matters as much as raw capacitance.
| Load current | Filter cap | Est. ripple pk-pk |
|---|---|---|
| 0.5A | 1000uF | about 5V |
| 1A | 2200uF | about 4.5V |
| 1A | 10000uF | about 1V |
| 2A | 4700uF | about 4.3V |
| 2A | 22000uF | about 0.9V |
| 3A | 33000uF | about 0.9V |
Capacitor input filters suit low to medium power with steady loads. For heavy current or tight ripple, oversizing C gets expensive; switch to a switching supply or add a choke. Always rate voltage at 1.5 times the peak.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Rectifier and filter design per GB/T 5226.1; capacitor selection to GB/T 2693 and IEC 60384. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.