A motor that spins but cannot carry the load accelerates slowly and trips overload is usually short of torque. This page lists the symptoms common root causes and a check order so you troubleshoot without wasted steps.
Insufficient torque is not a stall but the motor falling short of load demand: under rated load speed drops more than expected acceleration takes much longer inverter reports overcurrent or overload the motor heats yet output is small and the load shakes or stops. Unlike stall the motor still turns but cannot fill the demand.
Root causes fall into three families: power and parameter such as low voltage insufficient VFD torque boost low servo gain or wrong electronic gear giving a false position lag; mechanical such as load larger than design jammed transmission high friction gearbox efficiency drop or slip; motor body such as partial winding short rotor broken bar or magnet demagnetisation that drops servo torque.
Check order is electrical before mechanical: measure supply and inverter output current to confirm not low voltage or current limit; review parameters boost gain mode and electronic gear; then decouple the load and run free to see current and torque if free run is normal the problem is load or transmission; finally measure insulation and winding to rule out motor body fault. Rule: electrical before mechanical no load before loaded parameter before hardware.
| Check item | Symptom | Possible cause | Check first |
|---|---|---|---|
| Low supply volt | output drops proportional | grid drop line loss | measure input |
| VFD boost low | cannot carry low freq | param not set | add boost |
| Load over design | slow accel overheat | small margin | verify load |
| Transmission jam | large current noise | bearing lube | turn by hand |
| Motor body | torque drop heat | winding magnet | insulation |
For insufficient torque check electrical before mechanical and no load before loaded; first confirm current and voltage with a clamp meter then parameters and load and only then open the motor. Temporarily run slower or lighter but remove the root cause or it will overload and burn repeatedly.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Motor characteristic and drive see IEC 60034-1 and electrical safety see GB/T 5226.1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.