Six-step commutation control of brushless DC motors

Six-step commutation is the classic drive scheme for BLDC motors: exactly two phases conduct at any instant, and the sequence advances every 60 electrical degrees. Reading the commutation table and protecting the switching instants is the whole game.

1. How it works

The three-phase bridge has six switches, and each step routes current through two phases with the third floating, the Hall state deciding the path: conducting A+B- pulls the rotor toward the next position, the Hall edge fires, the controller switches to A+C-, and so on around the cycle. Commutation that lags or leads the ideal point sacrifices torque and aggravates ripple; the ideal moment aligns Hall edges with the back-EMF crossovers, and a small advance angle helps at high speed but too much flips into rectification and drags the rotor backward.

2. Practice and pitfalls

PWM rides on the conducting phases to set average current, usually on the high-side transistors at 10 to 20kHz so the tone leaves the audible band. The floating phase inductance must discharge through freewheeling diodes into the bus, pumping the bus voltage, so the bus capacitor is sized for the commutation ripple. Dead time of 0.5 to 2 microseconds is non-negotiable: shoot-through shorts the bus in microseconds and explodes the MOSFETs. Commission at 10 to 20 percent voltage while verifying all six steps against the table, then check phase-current symmetry, then full load.

3. Six-step conduction sequence quick table (forward)

Hall stateActive phasesCurrent pathStep
A high, B low, C highA+B-bus+ → A → B → bus-1
A high, B low, C lowA+C-bus+ → A → C → bus-2
A high, B high, C lowB+C-bus+ → B → C → bus-3
A low, B high, C lowB+A-bus+ → B → A → bus-4
A low, B high, C highC+A-bus+ → C → A → bus-5
A low, B low, C highC+B-bus+ → C → B → bus-6

4. Notes

The table assumes a 120-degree Hall layout and forward rotation; defer to the controller manual. Always start from low voltage with the current-limiting resistor fitted, since a wrong sequence at full voltage destroys MOSFETs instantly.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: See GB/T 21418 for brushless motor systems and controllers; safety of electronic control equipment per GB/T 5226.1 (IEC 60204-1). Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Omitting dead time between high- and low-side switches: shoot-through at commutation explodes the MOSFETs in microseconds and takes the bus capacitors with them
② Applying rated voltage before verifying the commutation table: a scrambled sequence surges current through windings and drivers alike
③ Running without the bus capacitor buffer at commutation: inductive pumping spikes punch through the switches, fine unloaded and fatal on load

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.