Starting difficulty often comes from unclear understanding of locked rotor torque. It is not true that bigger is always better but too small surely fails to start. This page explains the relation between locked rotor torque and starting ability and how to use it in selection.
Locked rotor torque also called starting torque T_st is the maximum torque the motor can output at zero speed while the rotor is held and energised; it is the first kick at the instant of start and decides whether the motor can move the load from rest. The associated locked rotor current at this moment is about 5 to 7 times rated for an async motor so the locked state must not last or the winding overheats in seconds.
Starting ability is not about whose locked rotor torque is biggest but about the margin over the load starting resisting torque. Practically require T_st at least 1.2 to 1.5 times the load static resisting torque; heavy belt conveyors and compressors take the upper limit. If the belt is tensioned and starts fully loaded the static resisting torque may approach rated so insufficient locked rotor torque cannot start and only no load or soft start works.
On site rule: measure the load static resisting torque first then compare with motor locked rotor torque leaving 20 percent margin. Pit one: watching only rated torque not locked rotor means light load runs but heavy load cannot start. Pit two: treating locked rotor current as normal running current and sizing the switch at 6 times trips it. Pit three: variable frequency start relies on torque boost so the locked rotor data of a power frequency motor must be converted to the set frequency first.
| Item | Meaning | Typical | Selection |
|---|---|---|---|
| Locked T_st | max torque at n=0 | (1.5~2.5)x rated | >=1.2x load |
| Lock current | start current | (5~7)x rated | size switch |
| Margin | T_st/load | 1.2~1.5 | too low no start |
| VFD start | torque by boost | low freq 0.5x | set boost |
| Heavy | belt compressor | upper margin | no load start |
First measure the load static resisting torque then select locked rotor torque with over 20 percent margin; heavy loads prefer no load or soft start. Locked rotor current only appears at start so protect at that multiple but never run locked for long.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Rotating machine starting see IEC 60034-1 and equipment safety see GB/T 5226.1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.