Buck, Boost and Buck Boost topologies compared

Buck steps down, Boost steps up and Buck Boost inverts or spans both; these three are the basic switching topologies. This page compares their input output relation, polarity and fit.

1. How it works

Buck chops the top switch and freewheels through the bottom diode or switch, delivering stored inductor energy to the load, so output is below input and same polarity. Duty D equals Uout over Uin and is under 1, efficiency up to 95 percent, the classic 12 V to 3.3 or 5 V for digital boards. Ripple is small in continuous mode; the downside is step down only, no isolation in the basic form.

2. Practice and pitfalls

Boost stores energy in the inductor while the switch conducts and releases it added to the input when off, so output is above input and same polarity. Above D 0.5 boost is clear, Uout equals Uin over (1 minus D), good for single cell to 5 V or PFC front ends. Never short the output and rate the switch voltage high; light load may enter discontinuous mode with bigger ripple.

3. Three topologies

TopologyOutputPolarity
Buckout under insame
Boostout above insame
Buck Boostup or downinverted
Buck DD under 1step down
Boost DD over 0.5step up
BB noteinvertedisolate GND

4. Notes

Use Buck to step down, Boost to step up, and Buck Boost for inverted or wide range conversion. Pick by the input output polarity relation, respect the inverted ground of Buck Boost, and size saturation current and switch stress per topology.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Switching topology per GB/T 5226.1; energy to IEC 62301 and IEC 60204-1. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Treating Buck Boost inverted output as positive blows the load; isolate its ground.
② Copying another topology component values mismatches switch stress and blows parts.
③ Insufficient inductor saturation current lets current run away at turn on and damages it.

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.

Related reading

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Electrical Knowledge Base · free self-study reference for electrical & automation engineers, 3D CAD models at MOULDL