Rules of thumb: DC circuits use 1.5~2× working voltage, input filtering 2×+, tantalum 3×. A 310V rectified bus takes 400~450V; ratings are continuous at 85°C - re-derate at higher ambient per the manufacturer curve.
AC circuits follow peak, not RMS: 220VAC peaks at 311V. Mains-connected positions demand safety classes - X across the line, Y to earth - never ordinary DC capacitors.
Ripple current heats the ESR and dries the electrolyte early. Compare switching-frequency ripple against the allowed-ripple table with 20%+ margin, parallel parts to share the heat, and expect half the life per 10°C above 70°C case temperature.
| Position | Suggested rating | Example | Key point |
|---|---|---|---|
| 24V control supply | ≥50V (2×) | 24V→50V electrolytic | Covers surge and heat |
| 310V DC bus | 400~450V | After 220V rectifier | 1.3~1.5× bus voltage |
| Tantalum positions | 3× working voltage | 5V→16V tantalum | 3× is the rule |
| 220V AC loop | AC-rated part | X2 275VAC | Peak 311V plus surge |
| SMPS output | 1.5~2× output | 12V→25V | Also check ripple current |
| High-ripple spots | +20% ripple margin | Parallel parts | Match the ripple table |
Voltage rating decides survival, ripple decides lifespan: set the rating by derating, set the part count by ripple current, then correct for ambient temperature.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Ratings and tests per GB/T 2693 series; power-electronic capacitor application per IEC 61071 and IEC 60831. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.