Motor torque speed curve drawing and reading

The torque speed curve on the motor catalogue is the core selection chart yet many only look at the rated point. This page explains how to draw it and read its four key points.

1. How it works

The curve has speed on the horizontal axis from 0 to synchronous n0 and torque on the vertical. Four key points: A start point n=0 torque T_st; B maximum point near n0 torque T_max; C rated point n_N torque T_N; D no load point near n0 torque near 0. The natural curve rises from A to B then falls to D.

2. Practice and pitfalls

Drawing: makers measure torque at various speeds in load test and connect the points; in field you can sweep with a torque meter and inverter under load. Reading: overlay the load torque line horizontal or varying and see if the intersection sits in the stable region below the curve. If the load line rises above the curve the motor stalls. Pit: comparing only rated point ignores the start segment and heavy start fails; pit: ignoring T_max a shock load above it stalls.

3. Torque speed curve key points table

Key pointSpeedTorqueMeaning
A start0T_stcan start
B maxnear n0T_maxstall limit
C ratedn_NT_Nsteady work
D no loadnear n0about 0free run
Load linevariesoverlaystable check
Pitrated onlymiss startfail

4. Notes

The curve four points are A start T_st at n=0 B max T_max near n0 C rated T_N at n_N and D no load near zero torque; overlay the load line and keep the operating point below the curve in the stable region. Never judge by rated point alone.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Rotating machine characteristics see IEC 60034-1 and electrical safety see GB/T 5226.1. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Comparing only rated point ignores start segment heavy start fails
② Ignoring T_max a shock load above it stalls the motor
③ Fan load line above curve means unstable running

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.