A big filter cap can draw a hundred ampere inrush at switch on; soft start ramps the voltage up so inrush stays within rating. This page covers resistor ramp, relay bypass and IC based schemes.
At switch on the cap is 0 V, a short, so inrush hits tens of times rated and stresses bridge, fuse and cap; repeated switching accumulates damage. Soft start inserts a limiter in the charge path so the cap voltage rises over tens to hundreds of milliseconds and current is clamped to a few times rated, then the limiter is bypassed for no steady loss.
A common method is a power resistor in series bypassed by a relay once the bus reaches threshold; R is about peak over allowed inrush, say 20 ohm for 310 V at 10 A, and power is by energy half C U squared or it blows. Rate the relay contact by steady current with margin, and watch for a stuck relay that leaves the resistor in and cooks the board.
| Option | Principle | Note |
|---|---|---|
| Series R | limit charge | power by energy |
| Relay bypass | short R steady | avoid stick |
| IC ramp | ramp ref | time tune |
| Ramp duty | slow output | needs ctrl |
| NTC | thermal limit | fails hot |
| Timed short | delay bypass | sense level |
Any large cap supply needs soft start; resistor plus relay is most common and an IC ramp is smoothest. Rate resistor power by half C U squared, relay current with margin, and guard against sticking and residual voltage on restart.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Inrush and soft start per GB/T 5226.1; module test to IEC 62310 and IEC 60204-1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.